Description
Electrical data
Protection class III (EN 61140)
Voltage supply Via FLEXBUS+
Power consumption ≤ 3.2 W
Internal power consumption ≤ 3.2 W 1)
Overvoltage category II (EN 61131-2)
Switching inputs
Terminals B1, B2
Input voltage 18 V DC … 30 V DC
Enabling current paths
Terminals 13/14, 23/24, 33/34, 43/44
Type of output Potential-free NO contacts, positively guided
Switching voltage 5 V AC/DC … 253 V AC/DC
Current-carrying capacity per OSSD 10 mA … 6 A
Signaling current paths
Terminals Y14, Y24
Type of output NO contact, connected to internal 24 V DC, positively guided, current-limited
Output voltage 16 V DC … 30 V DC
Output current ≤ 75 mA
Check-back current paths
Terminals Y1/Y2, Y3/Y4
Type of output Potential-free NC contacts, positively guided
Switching voltage 5 V AC/DC … 253 V AC/DC
Current-carrying capacity per OSSD 10 mA … 6 A